AMADA Fine Spot Welders AC controlled welding power suppies

AC controlled welding power supply: MEA-100B

Product Image

Best for precision resistance welding of small parts.



Features
■ Four welding current control systems are currently available for the MEA-100B. Select the control system best suited to the particular workpiece.
①Multi-Cycle Welding + Secondary Constant-Current Control
Returns welding current feedback to the control at each half-cycle, using the toroidal coil. The control makes adjustments based on this feedback to maintain a constant current, compensating for voltage fluctuation and workpiece load variances.
②Multi-Cycle Welding + Power Supply Voltage Fluctuation Compensation Control
Monitors and compensates for power supply voltage fluctuation to maintain a constant current. Compensation begins from the first half-cycle.
③Single-Cycle Welding + Power Supply Voltage Fluctuation Compensation Control
Permits the flow of one cycle current only. You can set the first half wave and the second half wave separately. Compensation begins with the first half wave.
④Half-Cycle Welding + Power Supply Voltage Fluctuation Compensation Control
Permits the flow of one half-cycle current only. The direction of the current is inverted with each current flow.
Controlling: current mode Multi-cycle welding Single-cycle welding Half-cycle welding
Power supply voltage fluctuation compensation control
Secondary constant-currenet mode
■ An automatic maximum current configuration.

The maximum current setting is automatically configured through test run to optimize the performance of the device.

■ The welding current is monitored using the a toroidal coil.

The upper and lower current limits can be fixed. This will aid the welding quality control.

■ Support for export.

CE marking and CCC supported. There are also 480V version for USA.


Specifications
 
Model MEA-100B
Power requirement Single-phase Automatic switching (The voltage can be switched, but the factory setting is fixed.)
Maximum capacity 60 kVA (Duty cycle: 1.3% when 200 V AC is input) / 66 kVA (Duty cycle: 1.3% when 220 V AC is input) / 68 kVA (Duty cycle: 2% when 380 V AC is input) / 72 kVA (Duty cycle: 2% when 400 V AC is input) / 86 kVA (Duty cycle: 2% when 480 V AC is input)
Control method 1. Secondary constant current control type
2. Power supply voltage fluctuation compensation control type
Welding current control 1. Multi - cycle welding
2. Single - cycle welding
3. Half - cycle welding
Control speed Half - cycle
Current accuracy For secondary constant current control ±2% max. of power supply voltage fluctuation ±10% ±2% max. of load fluctuation ±10%
±2% max. of load fluctuation ±10%
For power supply voltage fluctuation compensation control ±3% max. of power supply voltage fluctuation ±10%
Timer setting (31 schedules) Multi - cycle welding Squeeze, weld 1, cool, weld 2, hold ... 00 - 99cycles Upslope 1, upslope 2, downslope 0 - 9cycles Pulsation 1 - 9times
Single - cycle welding Squeeze, 00 - 99cycles First-half wave, second-half wave 0.5cycle
Half - cycle welding Squeeze, 00 - 99cycles Half wave 0.5cycle
Current value setting range (31 schedules) For secondary constant current control Current value 1, current value 2 ... 0.20 - 9.99kA (0.01kA unit)
For power supply voltage fluctuation compensation control Current value 1, current value 2 ... 10.0 - 99.9kA (0.1% unit)
Current monitoring (31 schedules) For secondary constant current control Upper limit setting: +1 to +49% Lower limit setting: -1 to -49%
For power supply voltage fluctuation compensation control Upper limit setting: 0.01 - 9.99kA (0.01kA unit) Lower limit setting: 0.01 - 9.99kA (0.01kA unit)
Options Toroidal coil MB-35E (Required for secondary constant current control)
External communication function Bi-directional communication
Ambient temperature and huidity Temperature = 0 to 45°C Humidity = 90% max.(No condensation)
Altitude: 1000meters or lower
Power consumption For standby 15W max.
Mass 6.5kg

Transformers that are selectable
 
Model MT-510AC MT-520AC MT-530A *1 MT-25, MT-25A
Rated capacity 1.0kVA 3.2kVA 6.0kVA
[4.2kVA]
11.1kVA
Rated primary voltage AC200V±10% (50/60Hz)
Non-load secondary voltage *1 1.2V/1.8V/2.5V/3.5V 2.5V/3.2V/4.0V/5.0V 2.7V [2.2V]/3.4V [2.8V]/
4.3V [3.6V]/5.3V [4.4V]
2.6V/4.0V(paralell)/5.3V/
8.0V(straight)
Turn Ratio 167:1/111:1/80:1/57:1 80:1/63:1/50:1/40:1 74:1/59:1/47:1/38:1 77:1/50:1/38:1/25:1
Maximum output current 1600A 3700A 6600A [5500A] 8000A
Duty factor (@100ms) 1.5% or below
Cooling method Air cooling Water cooling
CE marking - - - -: MT-25
◯: MT-25A
CCC
Mass 20kg 35kg 52kg 60kg
Dimensions *2 193(W)×284(D)
×175(H)
182.5(W)×358(D)
×197(H)
228(W)×370(D)×244(H) 180(W)×370(D)×240(H):MT-25
180(W)×463(D)×200(H):MT-25A

*1: Values at 60 Hz input are indicated in brackets [ ].
*2: Not including projections.


Customer support

If you have any questions as the products, reparing, and corporate information, plaese contact us.

Customer support