AMADA Fine Spot Welders DC Inverter controlled welding power supplies

For DC spot welding / fusing: IS-800A/1400A

Product Image

Precision waveform control ensures high quality welding!



Features
■ Primary current PEAK control enables detailed parameter settings.
The control features below are only available when Primary current PEAK is selected.
  • Voltage compensation
    It is to adjust set values for Pulse limit depending on primary voltage fluctuation before welding.
    • When 190VAC (-5%), pulse width set for Pulse limit is adjusted to increase 5%.
    • When 210VAC (+5%), pulse width set for Pulse limit is adjusted to decrease 5%.
  • Pulse limit
    This is to limit pulse width when current is up-sloping.
■ Ground fault and short-circuit protections ensure the safety better.
■ Adjustable welding frequency from 600 to 3000kHz with 100Hz increment.
■ Program protect feature prevents false operation due to unintended touches to the screen.
■ Up to the third welding is controllable. Pulsation and other control modes can be set for each welding.
■ Interrupt feature

Interrupt feature functions when a displacement amount reaches up to set level and stops current to obtain stable fusing. For this feature, it needs to be connected with a weld checker with a built-in displacement monitor and set a displacement amount of electrodes beforehand.

Interrupt feature

■ Six kinds of control methods

Select an optimal control method for an application: Primary current effective value control, secondary current effective value control, secondary power effective value control, Primary current peak value control, secondary voltage effective value control, and constant phase control.

■ Three kinds of monitoring

Current, voltage, or power can be monitored.

■ Safety features

Overcurrent detector, no-current/no-voltage detector, heat abnormality detector, and self-check feature protect your safety.

■ Two kinds of welding time unit

ms or cycle can be selected.

■ Duty factor and Output current

Duty factor and Output current

■ Samples

Samples


Specifications
 
Model IS-800A IS-1400A
Power requirements ・Three phase, 380-480VAC (50/60Hz)10%
・Three phase, 200-240VAC (50/60Hz)10%
・Three phase, 380-480VAC (50/60Hz)10%
・Three phase, 200-240VAC (50/60Hz)10%
Maximum output current 800A (3%) 1400A (3%)
Number of schedules 255
Output frequency 600Hz to 3kHz
Control method Primary current RMS/ Secondary current RMS/ Secondary power RMS/ Primary current PEAK/ Secondary voltage RMS/ Constant phase
Timer setting   msec mode cyc mode
SQUEEZE DELAY 0000 to 9999ms 000 to 999cyc
SQUEEZE 0000 to 9999ms 000 to 999cyc
UP SLOPE 1,2,3 000 to 999ms 00 to 50cyc
WELD 1,2,3 000 to 999ms 00 to 50cyc
DOWN SLOPE 1,2,3 000 to 999ms 00 to 50cyc
COOL 1,2 000 to 999ms 00 to 99cyc
HOLD 00000 to 20000ms 000 to 999cyc
OFF 0 or 0010 to 9990ms 00 to 99cyc
Transformer turn ratio 1.0 to 199.9
Pulsation setting 01 to 19
Valve setting 2
Setting range
(1)Constant current (2)Constant power (3)Constant voltage (4)Constant phase
(1)0.05 to 40.0kA (2)0.05 to 60.0kW (1)0.05 to 80.0kA (2)0.05 to 120.0kW
(3)0.20 to 9.99V (4)10.0 to 99.9% (3)0.20 to 9.99V (4)10.0 to 99.9%
Current monitor HIGH 0.00 to 9.99kA / LOW 0.00 to 9.99kA HIGH 00.0 to 99.9kA / LOW 00.0 to 99.9kA
Power monitor HIGH 0.00 to 9.99kW / LOW 0.00 to 9.99kW HIGH 00.0 to 99.9kW / LOW 00.0 to 99.9kW
Voltage monitor HIGH 0.00 to 9.99V / LOW 0.00 to 9.99V
Pulse width monitor 10 to 100%
Installation
environment
Ambient temp. +5 to +40℃
Max. humidity 90% (No condensation)
Max. altitude 1000m or below
Mass 38kg 60kg

 


Transformers that are selectable
 
  For IS-800A/1400A
Model SIT-F241-HC MIR109-69060 MIR115-39060
Rated capacity 75kVA (50%) 90kVA
Rated primary voltage 300V 600V/650V 300V/325V
No-load secondary voltage 12.5V 10.9V/11.8V 11.5V/12.5V
Transformer turns ratio 24:1 55:1 26:1
Input frequency 1kHz 600Hz/1kHz
Maximum welding current 14400A 18000A
Duty cycle 10%
Cooling method Water - coded
Mass 35kg 21kg 23kg
Dimensions (mm) * 240 (W) × 481 (D) × 180 (H) 167 (W) × 365 (D) × 155 (H) 167 (W) × 435 (D) × 155 (H)

* Include projections

It's one of examples. Thare are some transfomers that are able to use with the power supply.


Customer support

If you have any questions as the products, reparing, and corporate information, plaese contact us.

Customer support