AMADA Micro Welding Section Fine Spot Welders AC Inverter Controlled Welding Power Supplies

For AC precision spot / Series / Fusing welding: MIB-300A/600A

Product Image

Use AC transformer and improve heat efficiency.
Reduce magnetize and peltier effect on work piece.



Features
■ Able to keep on using AC welder transformer if you already have

No need to buy new weld head and transformer if you are already using AC welder for production

■ Reduce burn of coating materials while fusing

Reduce burn of coating materials while fusing

■ Reduce slant abrasion of electrode and unequal size of welding nugget

Reduce slant heat on one material while welding different material (peltier effect), reduce slant abrasion of electrode and unequal size of welding nugget.

■ Reduce magnetize of work piece around electrode

Reduce magnetic material around welding current being magnetized.

■ Add secondary constant current control

Since welding current will be monitored and controlled directly, able to have higher current control than primary constant current control.

■ Increase number of maximum pulsation

Previous unit: 9 times pulsation maximum → MIB-300A/600A: Maximum 20 times for each WELD1 to WELD3
Since it suppresses the rapid heating to the work by repeating the welding time and the pause time, it becomes easier to control the amount of displacement compared with continuous welding for a long time.

■ Able to set interrupt, up slope and down slope for all waveform (WELD1 to WELD3)

Interrupt function (Stop current when displacement value reaches to set level, go on to next step) will avoid work piece to be squashed, able to have more precise setting for welding condition.

Able to set interrupt, up slope and down slope for all waveform


Specifications
 
Models MIB-300A-00-00 MIB-300A-00-01 MIB-600A-00-00 MIB-600A-00-01
Power requireents 3 phase AC200~240V±10%(50/60Hz) 3 phase AC380~480V±10%(50/60Hz) 3 phase AC200~240V±10%(50/60Hz) 3 phase AC380~480V±10%(50/60Hz)
Maximum output current 300A 600A
Number of schedules 255
Output frequency 50, 53, 56, 59, 63, 67, 71, 77, 83, 91, 100, 111, 125, 143,167, 200, 250, 294, 417, 500Hz (Initial setting is 63 Hz.)
Frequencies in bold are available only when FREQ MODE (START) is set to PWM-OFF.
Control method Primary constant-current peak value control /
Secondary constant-current peak value control /
Secondary constant-current effective value control
Timer setting
(255)
SQUEEZE DELAY 0000 to 9999ms
SQUEEZE 0000 to 9999ms
UP SLOPE 1,2,3 00.0 to 99.5cyc
WELD 1,2,3 00.0 to 99.5cyc
DOWN SLOPE 1,2,3 00.0 to 99.5cyc
COOL 1,2 00.0 to 99.5cyc
HOLD 00000 to 20000ms
OFF *1 0 or 0010 to 9990ms
Transformer turn ratio 1.0 to 199.9
Pulsation setting 01 to 20
Valve setting 2valves (VALVE1, VALVE2)
Setting range 40kA range - 02.0 to 40.0kA
20kA range 0.1kA to 20.0kA 01.0 to 20.0kA
10kA range 0.50 to 9.99kA 0.50 to 9.99kA
5kA range 0.05 to 5.00kA 0.05 to 5.00kA
Monitor display Current 00.0 to 99.9kA/0.00 to 9.99kA
Voltage 0.00 to 9.99V
Cooling method Cooling with air Cooling with water Flow rate: 2L/min Water temperature: 35°C max.
External communication RS-232C/ RS-485(Simplex and duplex)
Operating environment Ambient temperature +5 to +40℃
Humidity 90% max.(no condensation)
Altitude 1000m以下
Mass 16.5kg 38kg

*1: Set at the factory


Transformers that are selectable
 
  For MIB-300A
Model MT-510AC MT-520AC MT-530A*1 MT-25
Rated capacity 1kVA 3.2kVA 6.0kVA [4.2kVA] 11.1kVA
Rated primary voltage 200VAC ±10%(50Hz/60Hz) 200VAC ±10%(50Hz/60Hz) 200VAC ±10%(50Hz/60Hz) 200VAC ±10%(50Hz/60Hz)
No-load secon-
dary
voltage
1.2V/1.8V/2.5V/3.5V 2.5V/3.2V/4.0V/5.0V 2.7V[2.2V]/3.4V[2.8V]/
4.3V[3.6V]/5.3V[4.4V]
2.6V/4.0V(paralell)/
5.3V/8.0V(straight)
Trans-
former
turns ratio
167:1/111:1/80:1/57:1 80:1/63:1/50:1/40:1 74:1/59:1/47:1/38:1 77:1/50:1/38:1/25:1
Maximum welding current 1600A 3700A 6600A [5500A] 8000A
Duty cycle 1.5% or less 2% or less 1.5% or less 1.5% or less
Cooling method Air cooling Water cooling
Mass 20kg 35kg 52kg 60kg
Dimen-
sions
(mm) *2
193(W) × 284(D) × 175(H) 182.5(W) ×358(D) × 197(H) 228(W) × 370(D) ×244(H) 180(W) × 370(D) × 240(H)

*1: Values at 60 Hz input are indicated in brackets [ ].

 

  For MIB-600A
Type Tap less
Model WT-A56241-220 WT4N-115-205-H-A
WT4N-115-205-Z-A
WT4N-125-206-H-A
WT4N-125-206-Z-A
WT4N-175-206-H-A
WT4N-175-206-Z-A
Rated capacity 56kVA 115kVA 125kVA 175kVA
Rated primary voltage 220(50Hz) 200V(50Hz) 200V(60Hz) 200V(60Hz)
No-load secondary voltage 9.1V 9.5V 10.5V 13.3V
Transformer turns ratio 24:1 21:1 19:1 15:1
Cooling method Water  
Mass 45.5kg 123kg 116kg 140kg
Dimensions(mm)*2 125(W) × 515.3(D)
×200(H)
197(W) × 598(D)
×260(H)
197(W)×578(D)
×260(H)
197(W) × 628(D)
× 260(H) 
  For MIB-600A
Type Tap changing
Model WT4T-70-200-H-A      
WT4T-70-200-Z-A
WT4T-90-415-H-A       
WT4T-90-415-Z-A
WT4T-110-446-H-A   
WT4T-110-446-Z-A
WT4T-135-446-H-A      
WT4T-135-446-Z-A
WT4T-190-446-H-A
WT4T-190-446-Z-A       
Rated capacity 70kVA 90kVA 110kVA 135kVA 190kVA
Rated primary voltage 200V(50/60Hz) 415V(50Hz) 440V(60Hz) 440V(60Hz) 440V(60Hz)
No-load secondary voltage TAP1, 6.4V
TAP2, 8.0V
TAP1, 6.3V
TAP2, 7.6V
TAP1, 7.4V
TAP2, 9.1V
TAP1, 9.7V
TAP2, 11.5V
TAP1, 12.2V
TAP2, 14.6V
Transformer turns ratio TAP1, 31:1
TAP2, 25:1
TAP1, 65:1
TAP2, 54:1
TAP1, 59:1
TAP2, 48:1
TAP1, 45:1
TAP2, 38:1
TAP1, 36:1
TAP2, 30:1
Cooling method Water
Mass 106kg 106kg 100kg 119kg 134kg
Dimensions(mm)*2 197(W) × 564(D) × 260(H) 197(W) × 564(D) × 260(H) 197(W)×544(D)×
260(H)
197(W) ×604(D) × 260(H) 197(W) × 654(D) × 260(H)

*2: Not including projections

Models H and Z of the tapless type and tap changer type indicate the core material, and when used in an AC inverter type, the Z type is recommended.

H: Standard type  Z: Low iron loss type

 


Customer support

If you have any questions as the products, reparing, and corporate information, plaese contact us.

Customer support