AMADA Fine Spot Welders checkers and Testers NEW

WELD CHECKER® (desk-top type) MM-400B

Product Image

Visible, Judge and control of welding parameter.
Long time measuring is available!


Features
■ 【MM-400B】

Measures current, voltage, welding time, weld force and displacement!

Supports a wide range of welding machines
The instrument supports single-phase AC, DC inverter, AC inverter, transistor, and capacitive discharge welding machines.
Various measurement functions
Easy to use with a touch panel.Display waveforme up to 4 items. Display and judge the parameters of the welding quality determinant up to 10 items.

Display screen
Display screen

ISO17657-compliant measurement
In addition to the arithmetic mean RMS which is a conventional calculation system, the RMS in a whole current flow time which is the ISO17657 (Resistance welding -- Welding current measurement for resistance welding -- )-compliant calculation system can be selected. For the ISO17657-compliant measurement, the dedicated ISO-compliant toroidal coil is required.
Supports multiple languages
Languages available are Japanese, English, Chinese, Korean, German, French, and Spanish.
■ New Features
Envelope function
Making the OK/NG judgment by comparing a waveform within an allowable range and a monitored waveform, enables management with waveforms in addition to conventional measured values.
(Up to 3 points 2 waveforms)

Envelope function

Measuring displacement Before-Welding
Measures Before-welding workpiece thickness, judge OK/NG of thickness.
■ Memory / Comumication / Printing
Memory
Measured values and waveforms can be saved in a built-in flash memory device/external USB.
Comunication
RS-232C, RS-485, Ethernet Simplex and duplex communication possible.(option)
Printing
Measured data and wavefome can be printing.
■ Judgment / Control function
  • By using a built-in force sensor / displacement sensor, it is possible to measure changes in pressurizing force / displacement amount even during production, display waveforms, judge OK/NG of welding.
  • Weld stop function shifted from 2 outputs to 3 outputs. Fine control of changes in displacement and applied pressure during welding.
  • With external input function, voltage input (± 10 V) current input (4 to 20 mA) from other sensors such as temperature sensor can be measured, waveform display, and OK/NG judge possible.
■ Long time measurement:MM-400B-02-05
  • Current and voltage are maesured in a maximum of 10 sec in AC/DC welding.

Measurement method

Measurement method

Measurement method

 


Specifications
 
MODEL       MM-400B-00-00/-00-01※1                            MM-400B-02-05                    
Measurement
specification
Current Range 1×Sensitivity toroidal coil:0.100~2.000kA/0.30~6.00kA/1.00~20.00kA/3.0~60.0kA/10.0~200.0kA
10×Sensitivity toroidal coil:0.010~0.200kA/0.03~0.60kA/0.100~2.000kA/0.30~6.00kA/01.00~20.00kA
Accuracy ±1% of full scale of each range(Excluding sensor's error)

Current sensor:1.00~20.00kA
Accuracy
<RMS>
Single phase AC welder ±(1%rdg+9dgt)kA
AC/DC Inverter ±(1%rdg+15dgt)kA
<Peak>
AC Welder ±(1%rdg+9dgt)kA
AC/DC Inverter ±(1%rdg+20dgt)kA
Current sensor ±(1%FS+8dgt)kA
      ±(0.1%FS)kA/℃(Temperature characteristic)       

Item PEAK/RMS*2/Arithmetic mean RMS PEAK/Arithmetic mean RMS
Voltage Range 0.30~6.00V/1.0~20.0V Accuracy ±1% of full scale of each range (Excluding sensor's error)
Items PEAK/RMS*2/Arithmetic mean RMS PEAK/Arithmetic mean RMS
Force*1 Range

4.90~98.06N(MA-520B)、49.0~980.6N(MA-521B)、245~4903N(MA-770A※3)、
490~9806N(MA-522B、MA-771A※3)

Items Mean RMS/PEAK Before welding/After welding/Constant   
Accuracy ±3% of full scale (Excluding sensor's error)
Displacement*1 Range

When the increment is 1μm:±30.00mm  Accuracy ±30.000mm range:±15μm (sensor with 1μm or less resolution)

When the increment is 10μm:±300.00mm  Accuracy ±300.00mm range:±150μm (sensor with 1.1μm or more resolution)

Items Before welding/After each welding/Constant
External Voltage and Current Range -10 to +10V or 4 to 20mA
Range 5% to 100% of rated setting
Items Mean RMS/PEAK Before welding/After welding/Constant Accuracy ±3% of full scale (Excluding sensor's error)
Units V/N/kgf/Ibf/℃/℉/Mpa/bar/psi

Measurement 
time

Current
Voltage
Displacement*1
Power
Resistance
AC ms-AC:1~5000ms
CYC-AC:0.5~250.0CYC(50Hz)、0.5~300.0CYC(60Hz)
CYC***Hz-AC:0.5~200.0CYC(M050:50Hz)、0.5~300.0CYC(M063:63Hz)、0.5~2000.0CYC(M500:500Hz)
LONG CYC-AC:0.5~500.0CYC(50Hz)、0.5~600.0CYC(60Hz)

ms-AC:1~10000ms
CYC-AC:0.5~500.0CYC(50Hz)、0.5~600.0CYC(60Hz)
CYC***Hz-AC:0.5~500.0CYC(M050:50Hz)、0.5~600.0CYC(M063:63Hz)、0.5~3000.0CYC(M500:500Hz)
DC CYC-DC:0.5~100.0CYC(50Hz)、0.5~120.0CYC(60Hz)
ms-DC:1~2000ms
SHORT ms-DC:0.50~300.00ms(0.05ms increment)
CYC-DC:0.5~500.0CYC(50Hz)、0.5~600CYC(60Hz)
ms-DC:1~10000ms
Force*1,external 10~10000ms
Conduction angle Range 0 to 180 degrees   Accuracy:±9 degrees
Number of schedule 127 schedules
Specification Power supply Single phase AC100V~240V±10%(50/60Hz)
External data output RS-232C/RS-485/Ethernet (Protocol:TCP/IP)
Language Japanase/English/German/French/Spanish/Chinise/Korean)
Power consumption 40W(Max 50W when printer running)
Dimension 172(W)mm×288(D)mm×266(H)mm
Weight Approx. 5kg
Toroidal coil MB-400P*2/MB-800P*2/MB-45G*3
Shunt resistor*3 DS 500A/100mV(range between 25A and 500A)
DS 1000A/100mV(range between 50A and 1000A)

*1: Displacement and force sensors are only available for MM-400B-00-01 and MM-400B-02-05

*2: ISO17657-compliant

*3: Can not be used with MM-400B-02-05

* Force sensors, Displacement sensors, Current/Force sensors, and Toroical coil are all option.

* Specifications are subject to change without nocice.


Configuration diagram

Configuration diagram


Accessories

Accessories


Customer support

If you have any questions as the products, reparing, and corporate information, plaese contact us.

Customer support